Quectel EC25: SMS compatibility and AT notes

A well-documented LTE module for integrators. We did not test it; everything here is vendor documentation, with power design as the main failure risk.

4G LTE moduleLTE Cat4 (regional variants), UMTS, GSMNot tested by us — vendor specs only

Verdict

A well-documented LTE module for integrators. We did not test it; everything here is vendor documentation, with power design as the main failure risk.

Verification status: Not tested by us — vendor specs only

Specification and SMS behaviour

Chipset / moduleQuectel EC25 LTE module, LCC package, 32.0 × 29.0 × 2.4 mm
InterfacesUSB 2.0, UART, PCM, I2C, SDIO, SGMII. No PCIe.
Power supply3.3–4.3 V supply (typical 3.8 V); GSM transmit bursts require low-ESR bulk capacitance close to VBAT
AT command notes3GPP TS 27.007 / 27.005 command set plus Quectel extensions. Vendor documentation covers text and PDU mode SMS.
Concatenated (long) SMSVendor SMS application note describes concatenated sending (up to 7 parts); not tested by us.
Receiving SMS / OTPVendor documents the full receive path (+CMTI / AT+CMGR); not tested by us.
MMSQuectel publishes a separate MMS application note for this family; not evaluated by us.
Date testedNot tested by us — vendor documentation only (as of 2026-11)

Fields we could not verify are written as "Not verified" rather than filled with estimates.

Known failures and troubleshooting

  • The classic EC25 integration failure is power, not AT: undervoltage during GSM bursts resets the module — check VBAT sag under load.
  • The UART is a 1.8 V domain on some variants; a level mismatch damages the interface — follow the vendor level-shift reference.
  • On Windows the Quectel USB driver must be installed before any COM port appears.

Data sources

Sources: vendor-published specifications and application notes only. SMS Deliverer has not tested this module; nothing on this page is a test result, and unconfirmed fields are marked Not verified.

Related pages

Questions about this model

Has SMS Deliverer been tested with the Quectel EC25?

No. This page is a vendor-specification summary, not a test result. Fields without documentation are marked Not verified.

What kills most EC25 SMS integrations?

Power design. GSM transmit bursts pull heavy current; if VBAT sags, the module resets mid-send. Use low-ESR bulk capacitance and short supply runs.